AFSM states for the automatic water change.
The AFSM standard is very usefull for making this semi automatic water change. The software is available in the download section of the site.

There are many discussions about waterchanges for saltwater aquaria. Some people never change water (they only fill up the evaporated water) and some do a (partial) waterchange every single day. I change every week approx. 10% of the water content. A water change can be messy/wet when you have to get the water out of the system and also to get the fresh salt water back into the system. You also have to make the right mix of RO and salt for new fresh water and the mix has to be on the right temperature! Quite an operation to perform every week; unless you have an automatic procedure.


Waterchange and Poseidon AFSM
The dimensions of the aquarium and sump (filter) are based on that 10% amount of waterchange; the last compartment of the sump can hold 15% of a filled aquarium and sump content. This compartment is used for the water change. Below the P&ID of the system and the description. The water supply pump (opvoerpomp), TT02 (temperature sump), LT02 (sump waterlevel), the FT01 (supply flow) and a heater (H02), with the valves are part of the semi automatic water change.

State: DichtVoorWissel (close for change)
When pressing the “Zout” (salt) button for at least 3 seconds, all valves close and the supply pump is stopped. In normal operation the water level in the tank is about 0,5 cm above the overflow pipes when the supplypomp is active. All water above the water overflow in the tank is now drained to the sump. This is about 5-15L and will fill the last compartment of the sump to a 90% level. After 1 minute the next state is activated.

State: OpenAfvoer (open drain valve)
The valve of the drain is opened and the supply pump is started. Water is now pumped to the drain into an empty jerrycan. When the flow is under 25l/hour and the level is less than 1cm, the pump is stopped. The next state is activated.


State: ROVoorZoutAanmaak (Start the RO for making water)
The RO is started and is filling the last compartment of the sump to the level setpoint (parameter PRM$SumpLevelmax).
When already filled for 7cm, the extra heater is on. When the level setpoint is reached, the next state is activated.

State: ZoutToevoegen (add Salt)
Now that the right waterlevel is reached, the software calculates the amount of salt to be added to get a concentration of 35gr salt / liter.
Add the amount of salt by hand and start the statemachine again by pussing the Salt button (for at least 3 seconds). The next state is activated.

State: ZoutMix (Salt mixing)
The drain valve is closed, and the mix valve is opened. The supply pump is started and circulates the fresh mixture until the temperature in the last compartment exceeds the tank temperature. In most cases, the salt will also have dissolved completely by this point. If the required temperature is reached in less than 45 minutes, the system will continue mixing until the full 45-minute mixing period has elapsed. Check the salt concentration of the freshly prepared mixture. If the concentration is correct, restart the finite state machine by pressing and holding the Salt button for at least 3 seconds.
The recommended amount of salt is based on a concentration of 35 g/L. If salt losses occur, for example due to the skimmer, use the Poseidon Graph spreadsheet to calculate the required correction and determine the adjusted salt dosage.

State: ZoutWisselKlaar
All valves are closed and the water change is ready. When all valves are closed, state WachtenVoorStart (waiting for normal start) is activated. In this state the tank software is going to normal operation again.

Logging on the standard pen writer
When logging some of the signals during the change, it looks something like this (part of the filling and the mixing is painted on the digital writer below)

Translate